Roofing Trumbull Products TruLo® Lo Odor Asphalt TruLo® Lo Odor Asphalt The sweet smell of innovation TruLo® Lo Odor asphalt takes much of the annoying odor out of every hot asphalt job. Our patented technology is specifically formulated to neutralize asphalt odor without impacting asphalt performance. The result: 50% odor reduction compared to Trumbull® standard asphalt. What's more, testing shows TruLo® Lo Odor asphalt is significantly more effective at reducing odor-causing compounds than leading competitive low-odor asphalts and additives. That's key since odor sometimes leads to costly night and weekend scheduling. With TruLo® Lo Odor asphalt, you can avoid the problem. TruLo® Lo Odor asphalt can be used at even the most odor-sensitive sites, such as schools, restaurants and hospitals. And because TruLo® Lo Odor follows the same kettle processing as standard asphalt, there is no messy, dangerous mixing of additives - so it works effectively to control odor both on the roof and at the kettle.Every shipment of TruLo® Lo OdorMeets or exceeds the physical requirements of the specified roofing grade asphalt (Meets ASTM D312) Offers consistent high flash material for consistent proper temperature range needed to apply product safely at the EVT; flash points typically 50ºF to 75ºF higher than the 500ºF minimum Is produced at one of our 13 plants, available from coast to coast Displays EVT on each carton and bill of lading for bulk shipments assuring proper adhesion, waterproofing and application rate Is packaged in printed cartons clearly identifying manufacturers, type, flash point, EVT, production location and production dateHow can I get TruLo® Lo Odor Asphalt? Our asphalt contact locator can help you find a distributor in your area. Features & Benefits Technical Documents Physical Characteristics FeaturesBenefitsMeets ASTM D31Each shipment meets or exceeds the physical requirements of the specified roofing grade asphaltConsistent high flash materialProper temperature range needed to apply product safely at the EVT; flash points typically 50ºF to 75ºF higher than the 500ºF minimum13 producing plantsConvenient, accessible availability from coast to coastEVT shown on each carton and bill of lading for bulk shipmentsAssures proper adhesion, waterproofing and application ratePrinted cartonsClearly identifies manufacturers, type, flash point, EVT TruLo® Lo Odor MSDSTruLo® Lo Odor Spec Sheet Typical Physical Characteristics for TruLo® Lo Odor Asphalt Type IType IIType IIIType IVSoftening Point (°F)140-150 165-175195-205210-225Flash Point (°F)525525525525Penetration, units, dmm: @77°F20-3520-3017-2415-22Ductility @77°F, cm134.03.02.0Solubility in Trichoroethylene %99.899.899.899.8Typical Application Temperature For Hand MoppingEVT @125 CPS +/- 25°F350375430530 For Machine SpreaderEVT @75 CPS +/- 25°F370395455475Physical Requirements - ASTM D312-00 Type IMin. Max.Type IIMin. Max.Type IIIMin. Max.Type IVMin. Max.Test MethodsSoftening Point (°F) 135 151158 176185 205210 225ASTM D36Flash Point (°F) 500 -500 -500 -500 -ASTM D92Penetration, Units, dmm: @32°F3 -6 -6 -6 -ASTM D5 @77°F18 60 18 4015 3512 25 @115°F90 180- 100- 90- 75 Ductility @77°F 10.0 - 3.0 - 2.5 -1.5 - ASTM D113Solubility in Trichoroethylene 99 - 99 - 99 -99 - ASTM D2042Asphalts shall be homogenous and free of water and shall conform to these physical properties Features & Benefits FeaturesBenefitsMeets ASTM D31Each shipment meets or exceeds the physical requirements of the specified roofing grade asphaltConsistent high flash materialProper temperature range needed to apply product safely at the EVT; flash points typically 50ºF to 75ºF higher than the 500ºF minimum13 producing plantsConvenient, accessible availability from coast to coastEVT shown on each carton and bill of lading for bulk shipmentsAssures proper adhesion, waterproofing and application ratePrinted cartonsClearly identifies manufacturers, type, flash point, EVT Technical Documents TruLo® Lo Odor MSDSTruLo® Lo Odor Spec Sheet Physical Characteristics Typical Physical Characteristics for TruLo® Lo Odor Asphalt Type IType IIType IIIType IVSoftening Point (°F)140-150 165-175195-205210-225Flash Point (°F)525525525525Penetration, units, dmm: @77°F20-3520-3017-2415-22Ductility @77°F, cm134.03.02.0Solubility in Trichoroethylene %99.899.899.899.8Typical Application Temperature For Hand MoppingEVT @125 CPS +/- 25°F350375430530 For Machine SpreaderEVT @75 CPS +/- 25°F370395455475Physical Requirements - ASTM D312-00 Type IMin. Max.Type IIMin. Max.Type IIIMin. Max.Type IVMin. Max.Test MethodsSoftening Point (°F) 135 151158 176185 205210 225ASTM D36Flash Point (°F) 500 -500 -500 -500 -ASTM D92Penetration, Units, dmm: @32°F3 -6 -6 -6 -ASTM D5 @77°F18 60 18 4015 3512 25 @115°F90 180- 100- 90- 75 Ductility @77°F 10.0 - 3.0 - 2.5 -1.5 - ASTM D113Solubility in Trichoroethylene 99 - 99 - 99 -99 - ASTM D2042Asphalts shall be homogenous and free of water and shall conform to these physical properties Related Pages TruLo®MaxPermaMop® Industrial/Specialty Asphalts Saturants and Coatings