Fiberglass Insulation

Fiberglas™ Insul-Quick® Insulation

Fiberglas™ Insul-Quick® Insulation

Fiberglas™ Insul-Quick® Insulation is a lightweight insulation composed of glass fibers bonded together in a semi-rigid, board-like form with a special high temperature binder.

Pipe and Mechanical Insulation Brochure PDF | 4.14 MB

Fiberglas™ Insul-Quick® Insulation

Fiberglas™ Insul-Quick® Insulation is a lightweight insulation composed of glass fibers bonded together in a semi-rigid, board-like form with a special high temperature binder.

Pipe and Mechanical Insulation Brochure PDF?V=1488766783000 | 4.14 MB

Specifications and Literature

Technical Information

Physical Properties

Property Test Method Value
Hot Surface Performance ASTM C411 Up to 850°F (454°C)
Maximum thickness 6" (152 mm)
Up to 650°F (343°C)
Maximum thickness 8" (203 mm)
Compressive Strength
at 10% Deformation
at 20% Deformation
ASTM C165
90 lb/ft2 (4309 Pa)
130 lb/ft2 (6225 Pa)
Nominal Density ASTM C303 3.0 pcf (48 kg/m3)
Water Vapor Sorption ASTM C1104 < 2.0% by weight, at 120°F (49°C), 95% R.H.
Shot Content ASTM C1335 Negligible
Composite Surface Burning Characteristics
Flame Spread
Smoke Developed
10
UL 723, ASTM E84 or CAN/ULC-S102
25
50

Standards Codes Compliance

  • ASTM C612, Mineral Fiber Block & Board Thermal Insulation, Types IA, IB, II
  • ASTM C795, Thermal Insulation for Use Over Austenitic Stainless Steel 11
  • Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation 11
  • U.S. Coast Guard Approval No. 164.109, Noncombustible Materials
  • CAN/CGSB-51.10–Type 1, Class 1

1. Includes core weight

2. All values are approximate.

3. Limited to single layer applications above 650°F (343°C), but not greater than 6" (152mm) thickness.

4. With heat up schedule.

5. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. Values are reported to the nearest 5 rating.

6. Preproduction qualification testing

7. It is critical to have the right amount of intake ventilation and to adequately seal the attic floor to prevent pulling air from conditioned space.

8. For each Gable Mount fan, Owens Corning Roofing requires 890 square inches of intake. See instructions for details.

9. For each Roof Mount fan, Owens Corning Roofing requires 600 square inches of intake. See instructions for details.

10. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.

11. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.

Applications

Mechanical Solutions

Mechanical Room

Piping

Flatwork

eBooks and Guides

Division 22/23 eBook

The Division 22/23 Mechanical Manufacturer’s Guide eBook is an easy-to-use tool that can be accessed anytime, anywhere to view duct, pipe and HVAC equipment insulation solutions, product data sheets, CSI MasterFormat® three-part system specifications and green building program guides.

3E Plus®

Owens Corning is proud to partner with 3E Plus® to deliver answers about using our insulation products in your business applications.

You can also download the 3E Plus® User Guide for any questions.

Find our Products

Find a Professional

CONTACT US

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative so you can start your project right away.

1-800-GET-PINK