Skip to main content
20149
Change

STEEL STUD WALL Masonry Veneer Mineral Wool CI with Fluid or Sheet AWB

Overview

This Enclosure Solutions Wall System includes a steel stud structure with masonry veneer, exterior gypsum sheathing, mineral wool continuous insulation & mineral wool cavity batt insulation. Complies with NFPA 285 (fire), ASTM E2357 (air), & ASTM E331 (water).

Get all the construction documentation you'll need, in a single click:

Products in this Solution

Additional Products

Sold Separately

Performance Attributes

Key Attributes:

Fire Resistance
Sound Reduction
Recycled Content
Thermal Comfort

ASHRAE 90.1 Compliant

ASHRAE Standard 90.1 requires Continuous Insulation (CI) be used for all commercial and some residential buildings in the United States. Continuous insulation is defined in 90.1 as “insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope”.

Learn More

ASTM E2307

ASTM E2307 measures the ability of perimeter fire barrier systems to maintain a seal and prevent interior fire spread as the exterior wall assembly deflects and deforms during fire exposure. The ASTM E2307 test exposes the joint to fire from the room of fire origin and the exterior wall to fire from both the interior and the exterior as the fire plume exits the room of fire origin through a window opening. ASTM E 2307 determines the period of time that the perimeter fire containment system will limit flame penetration through the opening between the exterior wall assembly and the floor assembly.

NFPA 285 Compliant

NFPA 285 is required in the International Building Code (IBC) in multiple situations. The NFPA 285 test is to determine that combustibles, when exposed to fire on the exterior face of the wall, do not spread flame over the surface or through the core of the otherwise non-combustible wall assembly.

Learn more at NFPA.org

Additional Attributes and Compliance

This wall assembly enclosure also meets the following codes and standards. Click a standard to learn more

Drawings

Construction Details including BIM objects and CAD drawing files for Steel Stud Enclosure Solutions Wall Systems are available for download below.

BIM Objects

Building Enclosure Steel Stud BIM Object

CAD Files

Panel System with Thermafiber® RainBarrier® 45 to Masonry CAD Drawing

Steel Stud Sill- Thermafiber Rainbarrier 45 Mineral Wool with Masonry Return and Wash Cavity Closure

Steel Stud Head- Thermafiber Rainbarrier 45 Mineral Wool CI with FRTW Blocking and Loose Angle Cavity Closure

Steel Stud Head-Thermafiber Rainbarrier 45 Mineral Wool CI with Steel Angle Cavity Closure

CONTACT US

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative so you can start your project right away.

1-800-GET-PINK®