The OptiLiner Banded Liner System is designed to maximize the thermal performance of Owens Corning EcoTouch Insulation for MBI Plus with PureFiber Technology light density fiberglass insulation in metal building roof and wall applications.
Fiberglass Insulation
OptiLiner® Banded Liner System
Specifications & Literature
Certifications
Performance Attributes
Acoustic Properties
Thermal Comfort
Moisture Management
Technical Information
Property | Test Method | Value |
|---|---|---|
Insulation
| ||
Noncombustibility
| ASTM E136
| Noncombustible |
Water Vapor Sorption
| ASTM C1104
| < 5% by weight |
Odor Emission
| ASTM C1304
| No objectionable odor1 |
Corrosion to Steel
| ASTM C1617
| Meets Requirements |
Fungi Resistance
| ASTM C1338
| Meets Requirements |
FACING | ||
Facing Permeance
| ASTM E96
| ≤ 0.02 perms |
Fungi Resistance
| ASTM C1338
| No growth greater than comparative item |